What are the misconceptions when adding liquid nitrogen?

Editor:adminClick: Time:2025-04-19 16:40
What are the misconceptions when adding liquid nitrogen? You may have overlooked these details
Liquid nitrogen, as an ultra-low temperature medium at -196 ℃, is widely used in scientific research, medical and other fields. However, many users often have misconceptions during the refueling process, and these overlooked details may pose security risks or affect storage effectiveness. Here are a few key considerations:
 
Misconception 1: Quick refueling is more efficient
Fact: Intense boiling of liquid nitrogen can lead to "explosion boiling" phenomenon, and splashing droplets may cause frostbite
Correct approach: The "slow fast slow" three-stage filling method should be adopted, with an initial flow rate controlled at 1L/min
 
Misconception 2: The fuller the liquid level, the better
Fact: Overfilling can cause the exhaust port to freeze and block, posing a risk of pressure accumulation
Professional advice: Reserve 10% -15% gas phase space, and it is recommended that the liquid level of medical grade liquid nitrogen tanks should not exceed 80% of the volume
 
Misconception 3: Neglecting environmental ventilation
Actual test data: 1 liter of liquid nitrogen vaporizes and expands to 700 times its volume, which may cause oxygen deficiency in a closed space (oxygen concentration<19.5% is considered dangerous)
Solution: Ensure that the air exchange rate in the operating area is ≥ 12 times/hour and equipped with an oxygen alarm
 
The most easily overlooked details:
 
Pre cooling stage: The new tank needs to be cooled in a stepped manner for the first use, with 1/3 of the capacity added each time and an interval of 30 minutes
 
Pipeline treatment: Before filling, blow the pipeline with dry nitrogen to avoid water freezing and blockage
 
Personal protection: Face mask type protective equipment must be worn, ordinary gloves cannot protect against -196 ℃ low temperature
 
Lesson from a certain biological sample library: Directly adding liquid nitrogen tanks without pre cooling resulted in shrinkage and cracking of the inner container, leading to the loss of valuable samples. Experimental results have shown that standardized pre cooling can extend the lifespan of the tank by 3-5 years. Remember: the safety margin of liquid nitrogen operation is hidden in the details that are easily overlooked.

Latest Products

110m3 double wall cryogenic Liqu
10m3 double wall cryogenic Liqu
Cryogenic Liquid Tanks are available in vertical or horizonta...[more]
2vertical stainless steel pressu
vertical stainless steel pressu
Cryogenic Liquid Tanks are available in vertical or horizonta...[more]
310 cubic meters cryogenic Liqui
10 cubic meters cryogenic Liqui
Cryogenic Liquid Tanks are available in vertical or horizonta...[more]
4GB150 pressure vessels cryogeni
GB150 pressure vessels cryogeni
Cryogenic Liquid Tanks are available in vertical or horizonta...[more]
5New double Vertical cryogenic L
New double Vertical cryogenic L
Cryogenic Liquid Tanks are available in vertical or horizonta...[more]

Rankings Of Similar Articles

Latest Information